Hey!

Currently doing drywall myself and I am using 6x6 cm squared timber around my outside walls.

The problem is they aren’t as stable as the other walls inside the house because of the 6x6 cm squared timbers that are about 30cm distance from each other.

I will screw my plasterboards on the squared timber and only one plasterboard, not two.

I have two pictures of what my construction looks like from far and one from close.

Maybe someone can give me advice before I install the plasterboard onto it.

The only problem I currently see is finding the subconstruction once I put the plasterboards back on. But other than that, if I find them can I install the cabinets safely?

      • Pohl@lemmy.world
        link
        fedilink
        arrow-up
        0
        arrow-down
        1
        ·
        edit-2
        7 months ago

        Yeah there is so much crazy shit going on in these pictures I am doubting my own understanding and I was a rough carpenter for several years.

        Why are the studs on the flat? Where the hell is that sill plate? No headers over the windows? No cripples under the windows? Is that stud next to the window opening cut at the bottom? Why are the studs spaced so… creatively

        I could probably spot a few more but I honestly think I just don’t know what this building is or where it is. Clearly not in US and maybe it’s a shed or something and not a dwelling. Too much I don’t know to talk shit.

        Edit: is there like an actual structural wall on the exterior that we cannot see? Maybe all this stuff is just to provide structure for drywall and electric. That would maybe make sense.

        • NegativeLookBehind@lemmy.world
          link
          fedilink
          arrow-up
          1
          ·
          edit-2
          7 months ago

          From the links he sent, it looks like he’s just building a non-structural insulating wall on the interior which allows for running electrical lines.

    • seathru@lemm.ee
      link
      fedilink
      English
      arrow-up
      0
      ·
      edit-2
      7 months ago

      Holy shit, is that load bearing plywood on the far wall (with the rectangle window).

      My friend, you need help from someone that knows what they are doing and familiar with local codes before proceeding any further.

      • Death_Equity@lemmy.world
        link
        fedilink
        arrow-up
        0
        ·
        7 months ago

        They are not American, Germans build way different so how they do things does not make sense without understanding what is going on.

        • Taleya@aussie.zone
          link
          fedilink
          arrow-up
          1
          ·
          7 months ago

          Not just germans, aussie here, assumed that was internal walls (which differ from external). Seen a few double brick/ concrete framed out like that

          Mind you our building standards have gone down the shitter since the 90’s…