Despite its name, the infrastructure used by the “cloud” accounts for more global greenhouse emissions than commercial flights. In 2018, for instance, the 5bn YouTube hits for the viral song Despacito used the same amount of energy it would take to heat 40,000 US homes annually.

Large language models such as ChatGPT are some of the most energy-guzzling technologies of all. Research suggests, for instance, that about 700,000 litres of water could have been used to cool the machines that trained ChatGPT-3 at Microsoft’s data facilities.

Additionally, as these companies aim to reduce their reliance on fossil fuels, they may opt to base their datacentres in regions with cheaper electricity, such as the southern US, potentially exacerbating water consumption issues in drier parts of the world.

Furthermore, while minerals such as lithium and cobalt are most commonly associated with batteries in the motor sector, they are also crucial for the batteries used in datacentres. The extraction process often involves significant water usage and can lead to pollution, undermining water security. The extraction of these minerals are also often linked to human rights violations and poor labour standards. Trying to achieve one climate goal of limiting our dependence on fossil fuels can compromise another goal, of ensuring everyone has a safe and accessible water supply.

Moreover, when significant energy resources are allocated to tech-related endeavours, it can lead to energy shortages for essential needs such as residential power supply. Recent data from the UK shows that the country’s outdated electricity network is holding back affordable housing projects.

In other words, policy needs to be designed not to pick sectors or technologies as “winners”, but to pick the willing by providing support that is conditional on companies moving in the right direction. Making disclosure of environmental practices and impacts a condition for government support could ensure greater transparency and accountability.

  • wewbull@feddit.uk
    link
    fedilink
    English
    arrow-up
    64
    arrow-down
    14
    ·
    7 months ago

    So… Absolutely need to be aware of the impact of what we do in the tech sphere, but there’s a few things in the article that give me pause:

    Research suggests, for instance, that about 700,000 litres of water could have been used to cool the machines that trained ChatGPT-3 at Microsoft’s data facilities.

    1. “Could”. More likely it was closed loop.
    2. Water isn’t single use, so even if true how does this big number matter.

    What matter is the electrical energy converted to heat. How much was it and where did that heat go?

    Moreover, when significant energy resources are allocated to tech-related endeavours, it can lead to energy shortages for essential needs such as residential power supply. Recent data from the UK shows that the country’s outdated electricity network is holding back affordable housing projects.

    Can you say non sequitur ?

    The outdated network holding back housing is that it doesn’t go to the right places with the capacity needed for the houses. Not that OpenAIUK is consuming so much that there’s no power left. To use a simily, there’s plenty of water but the pipes aren’t in place.

    This article is well intentioned FUD, but FUD none the less.

    • hummingbird@lemmy.world
      link
      fedilink
      English
      arrow-up
      13
      arrow-down
      7
      ·
      edit-2
      7 months ago

      “Could”. More likely it was closed loop. As I understand it this is an estimate, thus the word “could”. This has nothing to do with using closed or open look water cooling. Water isn’t single use, so even if true how does this big number matter.

      The point they are trying to make is that fresh water is not a limitless resource and increasing usage has various impacts, for example on market prices.

      The outdated network holding back housing is that it doesn’t go to the right places with the capacity needed for the houses. Not that OpenAIUK is consuming so much that there’s no power left. To use a simily, there’s plenty of water but the pipes aren’t in place.

      The point being made is that resources are allocated to increase network capacity for hyped tech and not for current, more pressing needs.

          • Lvxferre@mander.xyz
            link
            fedilink
            English
            arrow-up
            1
            ·
            7 months ago

            Not just corrosion, but also to prevent precipitation in evaporative cooling systems (the most common ones).

            Evaporative systems require constant input of new water; if you’re adding saltwater the salt will concentrate and it’ll become a saturated brine, and once the brine evaporates a bit the salt precipitates. It’ll happen mostly on the cooling fills (that will need to be replaced more constantly), but the main issue is that some precipitate does get carried by the brine and clogs the pipes.

        • morbidcactus@lemmy.ca
          link
          fedilink
          English
          arrow-up
          6
          ·
          7 months ago

          A lot of industry does use grey water or untreated water for cooling as it’s substantially cheaper to filter it and add chemicals to it yourself. What’s even cheaper is to have a cooling tower and reuse your water, in the volumes it’s used at industrial scales it’s really expensive to just dump down the drain (which you also get charged for), when I worked as a maintenance engineer I recall saving something like 1m cad minimum a year by changing the fill level in our cooling tower as it would drop to a level where it’d trigger city water backups to top up the levels to avoid running dry, and that was a single processing line.

    • Lvxferre@mander.xyz
      link
      fedilink
      English
      arrow-up
      3
      arrow-down
      4
      ·
      7 months ago

      “Could”. More likely it was closed loop.

      Nope. Here’s how data centres use water.

      It boils down to two things - cooling and humidification. Humidification is clearly not a closed loop, so I’ll focus on the cooling:

      • cold water runs through tubes, chilling the air inside the data centre
      • the water is now hot
      • hot water is exposed to outside air, some evaporates, the leftover is colder and reused.

      Since some evaporates you’ll need to put more water into the system. And there’s an additional problem: salts don’t evaporate, they concentrate over time, precipitate, and clog your pipes. Since you don’t want this you’ll eventually need to flush it all out. And it also means that you can’t simply use seawater for that, it needs to be freshwater.

      Water isn’t single use, so even if true how does this big number matter.

      Freshwater renews at a limited rate.

      What matter is the electrical energy converted to heat. How much was it and where did that heat go?

      Mostly to the air, as promoting the evaporation of the water.

      Can you say non sequitur ?

      More like non sequere than non sequitur. Read the whole paragraph:

      Moreover, when significant energy resources are allocated to tech-related endeavours, it can lead to energy shortages for essential needs such as residential power supply. Recent data from the UK shows that the country’s outdated electricity network is holding back affordable housing projects. This will only get worse as households move away from using fossil fuels and rely more on electricity, putting even more pressure on the National Grid. In Bicester, for instance, plans to build 7,000 new homes were paused because the electricity network didn’t have enough capacity.

      The author is highlighting that electrical security is already bad for you Brits, for structural reasons; it’ll probably get worse due to increased household consumption; and with big tech consuming it, it’ll get even worse.

      • Thrashy@lemmy.world
        link
        fedilink
        English
        arrow-up
        6
        ·
        edit-2
        7 months ago

        Data center cooling towers can be closed- or open-loop, and even operate in a hybrid mode depending on demand and air temps/humidity. Problem is, the places where open-loop evaporative cooling works best are arid, low-humidity regions where water is a scarce resource to start.

        On the other hand, several of the FAANGS are building datacenters right now in my area, where we’re in the watershed of the largest river in the country, it’s regularly humid and rainy, any water used in a given process is either treated and released back into the river, or fairly quickly condenses back out of the atmosphere in the form of rain somewhere a few hundred miles further east (where it will eventually collect back into the same river). The only way that water is “wasted” in this environment has to do with the resources used to treat and distribute it. However, because it’s often hot and humid around here, open loop cooling isn’t as effective, and it’s more common to see closed-loop systems.

        Bottom line, though, I think the siting of water-intensive industries in water-poor parts of the country is a governmental failure, first and foremost. States like Arizona in particular have a long history of planning as though they aren’t in a dry desert that has to share its only renewable water resource with two other states, and offering utility incentives to potential employers that treat that resource as if it’s infinite. A government that was focused on the long-term viability of the state as a place to live rather than on short-term wins that politicians can campaign on wouldn’t be making those concessions.

        • Lvxferre@mander.xyz
          link
          fedilink
          English
          arrow-up
          2
          ·
          7 months ago

          They can be closed-loop as in your region but they usually aren’t - besides the problem that you mentioned, a closed loop increases electricity consumption (as you’ll need a heat pump instead), and electricity consumption is also a concern. Not for the environmental impact (corporations DGAF), but price.